Customization: | Available |
---|---|
After-sales Service: | 14 Days |
Warranty: | 14 Days |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Hydrothermal synthesis reactor is also known as polymerization reactor, high pressure digestion tank/cans, organic synthesis reaction vessel and so on. This product is a closed container designed for digesting samples which are hardly dissolved by normal ways. It also can be used as a synthesis reactor. It can dissolve insoluble substances fast by using strong acids or strong alkalis in a tank amidst high temperature and high pressure, airtight environment.
The Hydrothermal Autoclave Reactor is used to carry hydrothermal reactions at high pressure and high temperature. And it's mainly made up of two parts; outer high-quality stainless steel jacket and inner PTFE liner or PTFE chamber.
Our unit digestion tank solved the customer in the process of digestion in a large number, high requirements, small volume and difficult to resolve the problem.Item name | Hydrothermal synthesis reactor |
Composition: | an outer pot (Stainless steel) and an inner cup (PTFE) |
Size | 5ml/10ml/15ml/20ml/25ml/30ml/50ml/60ml/100ml/150ml/200ml/250ml/500ml/1000ml Customization is accepted |
Material and temperature of inner cup | 1. The temperature resistance of domestic high purity experimental PTFE is less than 200ºC 2. Imported polytetrafluoroethylene TFM withstand 230-260ºC, pressure resistance, better recovery, low blank value of metal elements, lead, uranium content is less than 0.01ppb, no dissolution and precipitation |
Conditions of use | The whole set is put in the oven to withstand 5Mpa (50KG) |
Advantage | 1. Anti-high and low temperature. 2. Corrosion resistance 3. Low blank value of metal elements etc. 4. Used in the oven, easy to clean |
Note | 1. The amount of solvent added for digestion depends on different experiments, generally 1/3 to 1/5 of the inner cup capacity 2. If perchloric acid and hydrogen peroxide are used in the experiment, the dosage should not be too much, and cold nitrification should be carried out overnight 3. When the digestion is over, it is not easy to open because the internal pressure is too large, so it can be cooled to room temperature to open |
MOQ | 3pcs per size |
Sample time | 7 working days (Mass production time: 30 working days after received your deposit.) |
Payment | 30%TT and the balance should be paid before delivery. |
Our Advantages | 1.Customization is accepted |
2.High cost performance | |
3.In stock | |
4.Fine workmanship |